DC MCB
Non-polarized connection 1P & 2P versions High-rated breaking capacities up to 10 kA Rated current up to 100A Rated operating voltage: 300VDC(1P); 600VDC(2P).
Main Switch
Tested according to lEC/EN 60947-3 Rated short-time withstand current lcw=12 x le 1s 1 & 3-pole versions Rated current up to 125A Rated operational voltage 240/415V AC Built-in lock mech
RCBO
Residual Current circuit Breakers with Overload protection according to AS/NZS 61009:2015 Rated breaking capacity Icn 6 kA 1+N-pole version Rated residual current 30, 100, 300 mA Rated cu
RCBO
One-module Residual Current circuit Breakers with Overload protection accordingto EN 61009-1 Rated breaking capacity lcn 6 kA 1P+N-pole version Rated residual current 30 mA Rated currents
RCCB
Residual Current Circuit Breakers according to lEC/EN 61008-1 and IEC/EN 62423 Cond. rated short circuit strength Inc 10 kA B type 2 and 4-pole versions Rated residual current 30, 100 and
AC SPD
Surge Protection Devices Type 1+2(Classl+ll, T1+T2, B+C) Tested according to EN 61643-11 Max. impulse current limp 25 kA (10/350 us) per module and 100 kA for NPE module Maximum continuou
AC Fuse Holder
Meet requirements of EN 60947-3 Rated operating voltage 400/690 V AC Versions with rated current 32 A (10 x 38 mm) Utilization category AC-20B at 400/690 V AC Sealing possibility
Installation Contactors
Meet requirements of IEC/EN 61095 2 or 4-contact versions Rated current up to 25A, 40A, 63A Control coil voltage 24, 240V AC Various contact combinations
AC MCCB
Frame sizes M1-M5 Rated current up to 800A 3 and 4-pole versions Rated ultimate short circuit breaking capacity lcu up to 150kA lcs =100%lcu Rated voltage 415 /690 V AC Thermomagnetic r
AC Switch Disconnector
Frame sizes M1-M6 Rated current up to 1600A Tested according to EN 60947-3 AC current character 3 and 4-poles versions Rated operating voltage Ue up to 690V AC Fixed version
MCCB Accessories
Accessories for Ex9M line devices Auxiliary contacts synchronous with main contacts Signal contacts active on electrical tripping of the circuit breaker (tripping signal contacts) Shunt tr
Contactors
Four frame sizes with rated current up to 100A at 400V AC-3 3-pole versions Coil control voltage 24-415V AC Rated conditional short circuit current 50kA Suitable mainly for industrial app
Contactors
Meet requirements of IEC/EN 60947-4-1 Rated current up to 500A at 400V AC-3 3-pole version Coil control voltage 24-415V AC/DC Rated conditional short circuit current 50kA Suitable for in
Overload Relay
Five frame sizes with rated current up to 500A at 690V AC-3 3-pole version Tripping class 10A For director mounting onto Ex9C(S) contactor series or as a stand-alone device Suitable mainl
Shortened fork type busbars
1 and 3-phase versions 10 mm2 for 63 A or 16 mm2 for 80 A rated current Step between connection points 18 mm Fork type connection points Delivered without end caps
Plastic surface-mounted, IP65
Surface-mounted consumer units PHS Rated operational voltage 400V AC,1500V DC Degree of protection IP65 4 up to 48 modules 1 up to 4 rows Transparent door
Plastic flush White
Flush-mounted consumer units PNF Degree of protection IP40 8 up to 54 modules 1 up to 3 rows Transparent or white door
Plastic surface Transparent
Surface-mounted consumer units PNS Degree of protection IP40 8 up to 54 modules 1 up to 4 rows Transparent or white door
Change-Over Switch
Group Change-Over Switches Meet requirements of IEC EN 60947-3 Rated current from 16 A to 40 A Rated operating voltage 240/415 V AC Utilization category AC-22A Contact form ( I-O-II ) 1
DC MCB
Miniature Circuit Breakers up to 125A Tested according to IEC 60947-2 & UL 1077 High rated breaking capacity up to 20kA 1P & 2P Rated operating voltage: 110VDC(1P); 250VDC(2P) Wide range